Popular home blood pressure cuffs may not fit millions of adults

By Laura Williamson, ÃÛÑ¿´«Ã½ News

filmstudio/E+ via Getty Images
(filmstudio/E+ via Getty Images)

Lea en español

More than 17 million U.S. adults may be unable to get accurate blood pressure measurements at home from popular over-the-counter devices because the cuffs that come with these machines are too small or too large for their arms, new research shows.

The proportion of adults whose arm circumference didn't match the standard device cuff size was higher among Black adults, who are more likely to need home monitoring because of their greater risk for high blood pressure. Because of societal and historical inequities, Black adults are 30% more likely to have hypertension, or high blood pressure, than their white peers, and Black women face a 50% greater risk.

The findings were presented Friday at the ÃÛÑ¿´«Ã½'s Hypertension Scientific Sessions in Chicago and published in the journal .

"Many people think measuring blood pressure is simple, but actually, there are many steps that need to be taken to get an accurate reading," said lead study author Dr. Kunihiro Matsushita, a professor of epidemiology and medicine at Johns Hopkins Bloomberg School of Public Health and Johns Hopkins School of Medicine in Baltimore. "One issue is finding the right cuff size for an individual's arm size. If the cuff is too small, it will overestimate a person's blood pressure reading. If it is too large, it will underestimate their blood pressure reading."

High blood pressure is the leading cause of heart disease and stroke worldwide, affecting nearly half of adults in the U.S., many of whom may not realize they have it. Hypertension is diagnosed when the systolic, or top number, is consistently 130 or higher, or the diastolic, or bottom number, is 80 or more.

The AHA recommends home monitoring when someone is at risk for high blood pressure, to confirm a hypertension diagnosis and to determine if blood pressure treatments are working.

Prior research shows that readings won't be accurate if the wrong cuff size is used. A recent study in found a cuff that is too big caused about a 4 mmHg lower systolic reading, and a cuff that was much too small led to a nearly 20 mmHg higher reading – enough to miss someone who should be diagnosed with hypertension or improperly diagnose someone who does not have the condition.

In the new study, researchers evaluated cuff sizes for 10 popular home blood pressure monitoring devices sold by a large online retailer. Nine offered cuff sizes covering arm circumferences from 22 centimeters (about 8.7 inches) to 42 cm (about 16.5 inches), and one provided a cuff that covered 22 cm to 40 cm in arm circumference.

Using data from the 2015 to 2020 National Health and Nutrition Examination Survey, they analyzed arm circumference for 13,826 adults who were an average 47 years old. Nearly 7% – equivalent to 17.3 million adults – had arm circumferences that did not match the cuff sizes sold with the devices. The vast majority of people whose arms did not match the cuffs – 6.4%, or 16.5 million adults – had an arm circumference greater than 42 cm.

Among Black adults in the study, nearly 12% had an arm circumference that didn't match available cuff sizes, compared to about 7% of white adults and 5% of Hispanic adults.

Cuff sizes vary by model and manufacturer, and a range of sizes is not always available. suggests about half of adults in the U.S. with high blood pressure need a large or extra-large cuff.

One solution would be to change the size of the standard cuff, Matsushita said. Shifting cuff size range to fit 25 cm to 45 cm, instead of 22 cm to 42 cm, could make it a good fit for 2.3 million more adults in the U.S., the researchers concluded.

Accurate blood pressure readings can be difficult to obtain, both in the health care setting and at home, said Dr. Karen Margolis, a senior investigator at HealthPartners Institute in Minneapolis. She was not involved in the study.

Readings are subject to errors when proper procedures are not followed, Margolis said. Blood pressure also can increase in a health care setting because people become anxious, a situation referred to as "white coat hypertension."

"The best way to counteract those problems is to have accurate blood pressure measurements taken at home on a regular basis," she said.

Prior research shows that the majority of home blood pressure monitors people use are not validated, said Margolis, who was co-author of a from the AHA and American Medical Association on the importance of measuring blood pressure at home.

A list of validated machines can be found at . The website allows users to filter machines by available cuff size, brand, price range and other features.

Finding the right cuff size requires wrapping a tape measure around the arm halfway between the elbow point and the bony point of the shoulder to find the correct arm circumference, Margolis said. "About a dozen readings over a one- to two-week period taken properly on a validated machine using the correct cuff size are enough to determine whether a person has hypertension or needs a medication adjustment," she said.

According to AHA guidelines, the proper way to take a blood pressure reading is to sit in a chair with feet flat on the floor and the back supported. Either arm can be used, but the middle of the cuff should be placed on the upper arm at heart level against the skin, not over clothing.

Readings should not be taken within 30 minutes of eating, ingesting caffeine or exercising, and the bladder should be empty. Rest quietly for at least five minutes before taking a measurement and do not speak or move while taking it. Take multiple measurements one minute apart at roughly the same time every day.


ÃÛÑ¿´«Ã½ News Stories

ÃÛÑ¿´«Ã½ News covers heart disease, stroke and related health issues. Not all views expressed in ÃÛÑ¿´«Ã½ News stories reflect the official position of the ÃÛÑ¿´«Ã½. Statements, conclusions, accuracy and reliability of studies published in ÃÛÑ¿´«Ã½ scientific journals or presented at ÃÛÑ¿´«Ã½ scientific meetings are solely those of the study authors and do not necessarily reflect the ÃÛÑ¿´«Ã½â€™s official guidance, policies or positions.

Copyright is owned or held by the ÃÛÑ¿´«Ã½., and all rights are reserved. Permission is granted, at no cost and without need for further request, for individuals, media outlets, and non-commercial education and awareness efforts to link to, quote, excerpt from or reprint these stories in any medium as long as no text is altered and proper attribution is made to ÃÛÑ¿´«Ã½ News.

Other uses, including educational products or services sold for profit, must comply with the ÃÛÑ¿´«Ã½â€™s Copyright Permission Guidelines. See full terms of use. These stories may not be used to promote or endorse a commercial product or service.

HEALTH CARE DISCLAIMER: This site and its services do not constitute the practice of medical advice, diagnosis or treatment. Always talk to your health care provider for diagnosis and treatment, including your specific medical needs. If you have or suspect that you have a medical problem or condition, please contact a qualified health care professional immediately. If you are in the United States and experiencing a medical emergency, call 911 or call for emergency medical help immediately.